Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Fingerprinting of Doppler audio signals from the common carotid artery
Anna V Müller1, José M Amigo2,3,4, Nicoline R Wichmann5
1Department of Veterinary Clinical Sciences, University of Copenhagen, Dyrlægevej 16, DK-1870, Frederiksberg C, Denmark. avm@sund.ku.dk.
Abstract:
Audio fingerprinting involves extraction of quantitative frequency descriptors that can be used for indexing, search and retrieval of audio signals in sound recognition software. We propose a similar approach with medical ultrasonographic Doppler audio signals. Power Doppler periodograms were generated from 84 ultrasonographic Doppler signals from the common carotid arteries in 22 dogs. Frequency features were extracted from each periodogram and included in a principal component analysis (PCA). From this 10 audio samples were pairwise classified as being either similar or dissimilar. These pairings were compared to a similar classification based on standard quantitative parameters used in medical ultrasound and to classification performed by a panel of listeners. The ranking of sound files according to degree of similarity differed between the frequency and conventional classification methods. The panel of listeners had an 88% agreement with the classification based on quantitative frequency features. These findings were significantly different from the score expected by chance (p < 0.001). The results indicate that the proposed frequency based classification has a perceptual relevance for human listeners and that the method is feasible. Audio fingerprinting of medical Doppler signals is potentially useful for indexing and search for similar and dissimilar audio samples in a dataset.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical...
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Assessment of blood pressure in brachial artery(two-step method)