Related Experiment Video
Updated: Dec 28, 2025

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
The Self-Assessment Corner for Shoulder Strength: Reliability, Validity, and Correlations With Upper Extremity
Philippe Decleve1,2, Joachim Van Cant2, Ellen De Buck1
1Department of Rehabilitation Sciences and Physiotherapy, Faculty of Medicine and Health Sciences, University Hospital Ghent, Belgium.
Context:
Rotator cuff weakness and rotation ratio imbalances are possible risk factors for shoulder injury among overhead athletes. In consensus statements, organizations have highlighted the importance of a screening examination to identify athletes at risk of injury. The screening should be portable and designed to be feasible in many different environments and contexts.
Objective:
To evaluate the reliability and validity of the Self-Assessment Corner (SAC) for self-assessing shoulder isometric rotational strength and examining whether performance on 2 physical performance tests was correlated with isometric shoulder rotational strength using the SAC in handball players.
Design:
Cross-sectional study.
Setting:
Sport setting.
Patients Or Other Participants:
A first sample of 42 participants (18 men, 24 women) was recruited to determine the reliability and validity of the SAC. In a second sample of 34 handball players (18 men, 16 women), we examined correlations between physical performance tests and the SAC.
Main Outcome Measure(S):
The SAC was used to measure isometric rotational strength with the upper extremity at 90° of abduction in the frontal plane and 90° of external rotation and the elbow flexed to 90° with neutral rotation of the forearm. The SAC findings were compared with those from manual testing. Results from the seated medicine ball throw (SMBT) and closed kinetic chain upper extremity stability test (CKCUEST) were used to establish relationships with the SAC. We calculated intraclass correlation coefficients to determine relative reliability and used standard error of measurement and minimal detectable change to quantify absolute reliability. Relationships among the different strength-testing procedures and with the physical performance tests were determined using the Pearson product moment correlation coefficient (r) or Spearman rank correlation coefficient (rs).
Results:
We observed good to excellent reliability (intraclass correlation coefficient [2,k] range = 0.89 to 0.92). The standard error of measurement varied from 3.45 to 3.48 N. The minimal detectable change with 95% confidence intervals ranged from 8.06 to 8.13 N. Strong correlations were present among strength procedures (r = 0.824, rs range = 0.754-0.816). We observed moderate to strong correlations between the CKCUEST findings and rotational strength (r range = 0.570-0.767). Moderate correlations were found between rotational strength and SMBT (r range = 0.573-0.626).
Conclusions:
The SAC is a clinically applicable and standardized protocol for self-assessing rotational strength in young healthy adults without pathologic conditions. Performance on the SMBT and CKCUEST may be valuable as a screening tool to further assess shoulder strength.
Related Concept Videos
Reliability and Validity
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
Spearman's Rank Correlation Test
Spearman's test calculates correlation by...
Self-Report Tests of Personality
Self-Esteem
Self-Evaluation Maintenance Model