Introduction:
In 2006, the North Denmark Region implemented the electronic prehospital patient medical record (PPR), amPHI, in the region's prehospital emergency medical service. In 2015, a new nationwide version was implemented. Our aim was to investigate the completeness and correctness of registrations of vital sign data in the PPR after the initial introduction and after the implementation of the new PPR version.
Methods:
This was a descriptive registry-based study including patients to whom an ambulance was dispatched after an emergency call in the North Denmark Region in the periods 2007-2014 and 2016-2017. We examined vital sign data defined as blood pressure (BP), heart rate (HR), blood oxygen saturation (SpO2), respiratory rate (RR), Glasgow Coma Scale (GCS) score and numeric rating scale (NRS) for pain. We defined incorrect vital sign values according to clinical plausibility. We used a trend analysis and Pearson's χ2.
Results:
We included 253,169 PPRs. The proportion of PPR with registration of vital signs from 2007-2014 compared with 2016-2017 was BP: 73-86%, 81-82%; HR: 76-88%, 82-83%; SpO2: 72-85%, 82-83%; RR: 34-82%, 77-79%; GCS score: 54-92%, 81-84%; NRS for pain: 0-16%, 24-26%. The increase from 2007-2014 and 2016-2017 was significant as were the differences between 2014 and 2016. We found few defined outliers (0.5%).
Conclusions:
The completeness of registration increased gradually but decreased slightly after implementation of the new version. A high completeness combined with few implausible outliers and concordance indicate correctness of the vital sign registrations.
Funding:
none.
Trial Registration:
Approval for the use of data was given by the medical director of the Emergency Medical Services, the North Denmark Region.
More Related Videos
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
05:01A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Data Reporting and Recording
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Types of Records I: Unit and Nurses Records
Unit records can be divided into two main types: administrative records and clinical records.
Administrative records in...