Related Experiment Video
Updated: Dec 28, 2025

A Microfluidic Model of Biomimetically Breathing Pulmonary Acinar Airways
Published on: May 9, 2016
Device-handling study of a novel breath-actuated inhaler, Synchrobreathe®, versus a pMDI
Santhalingam Balamurugan1, Komalkirti Apte2, Bhanu Pratap Singh3
1Sri Muthukumaran Medical College Hospital and Research Institute, Chennai, India.
Introduction:
Synchrobreathe®, a new-generation, novel breath-actuated inhaler (BAI) can address the key issues arising during the use of both pressurised metered dose inhalers ([pMDIs]; hand-breath coordination) and dry powder inhalers ([DPIs]; high inspiratory flow required) with respect to optimal drug deposition.
Materials And Methods:
This was an open-label, prospective, 2-week, multicentre study that assessed device handling, ease of use, errors and participant perception regarding the use of Synchrobreathe® versus a pMDI in patients with chronic obstructive pulmonary disease (COPD) (n = 162) or asthma (n = 239) and inhaler-naïve healthy volunteers (n = 59). Ability to use the device without errors at the first attempt, total number of errors before and after training, time taken to use the device correctly and total number of training sessions, and number of attempts to perform the correct technique on Day 1 and Day 14 were evaluated. Device handling and preference questionnaires were also administered on Day 14.
Results:
Of 460 participants, 421 completed the study. The number of participants using Synchrobreathe without any error after reading the patient information leaflet (PIL) was significantly low (p < 0.05) on Day 1. On Day 14, significantly more number of participants used Synchrobreathe without any error (p < 0.001). The total number of errors before and after training with Synchrobreathe was significantly less (p < 0.001). The average time required to perform the inhalation technique correctly (p < 0.01) and the total number of attempts (P < 0.001) with Synchrobreathe were significantly lower. The average number of attempts to inhale correctly was significantly (p < 0.001) less with Synchrobreathe on Day1 and Day 14. Most participants rated Synchrobreathe as their choice of inhaler.
Conclusion:
Synchrobreathe is an easy-to-use and easy-to-handle device with significantly less number of errors, which may have positive implications for disease control in asthma and COPD.
More Related Videos
04:59Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Related Concept Videos
Inhaled Medications
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...