Practical radiation dosimetry across a variety of CBCT devices in Radiology
Emer Kenny1, David Caldwell1, Mandy Lewis1
1Medical Physics, Mater Misericordiae University Hospital, Dublin, Ireland.
Abstract:
Cone beam technology is becoming more prominent in Radiology. In our hospital we have an extremity CT, an O-arm and a number of C-arms offering 3D capabilities. Each of these modalities use cone beam CT (CBCT) technology to image the area of interest in one single rotation. Traditional CTDI metrics for radiation dosimetry in CT depend on narrow beam geometry. The relevance of the CTDI as a dose indicator for cone beam scanning is contentious due to underestimation of dose lying outside the standard 100 mm chamber length and CTDI phantoms being of insufficient length. In an attempt to better quantify dose from cone beam scanning, alternative methodologies have been developed which attempt to counter the limitations of CTDI methodologies. In this comparison study we utilised the CBCT methodologies outlined in (i) IAEA Report 5, (ii) EFOMP's protocol on QC in CBCT and (iii) conventional CTDI measurement and tested them on various CBCT systems used in Radiology. These methods were chosen as they use equipment that is typically available to a diagnostic imaging physicist. We determine that the EFOMP protocol and the conventional CTDI method produce the best estimate of the radiation output for quality control purposes. Our conclusion is that the EFOMP protocol is the fastest and easiest method to measure a CBCT metric but it is not always accessible. For the systems in our hospital we will adopt the EFOMP protocol for open systems (C-arms) and perform CTDIVol measurements using conventional techniques on enclosed systems (O-arm and extremity CT).
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET