Related Experiment Video
Updated: Dec 28, 2025

Digital Analysis of Immunostaining of ZW10 Interacting Protein in Human Lung Tissues
Published on: May 1, 2019
Digital Whole Slide Imaging Compared With Light Microscopy for Primary Diagnosis in Surgical Pathology
Alexander D Borowsky1, Eric F Glassy2, William Dean Wallace3
1From the Department of Pathology and Laboratory Medicine, University of California, Davis, Sacramento (Borowsky, Bishop, Darrow, Gui, Jen, Walby).
Context.—:
The adoption of digital capture of pathology slides as whole slide images (WSI) for educational and research applications has proven utility.
Objective.—:
To compare pathologists' primary diagnoses derived from WSI versus the standard microscope. Because WSIs differ in format and method of observation compared with the current standard glass slide microscopy, this study is critical to potential clinical adoption of digital pathology.
Design.—:
The study enrolled a total of 2045 cases enriched for more difficult diagnostic categories and represented as 5849 slides were curated and provided for diagnosis by a team of 19 reading pathologists separately as WSI or as glass slides viewed by light microscope. Cases were reviewed by each pathologist in both modalities in randomized order with a minimum 31-day washout between modality reads for each case. Each diagnosis was compared with the original clinical reference diagnosis by an independent central adjudication review.
Results.—:
The overall major discrepancy rates were 3.64% for WSI review and 3.20% for manual slide review diagnosis methods, a difference of 0.44% (95% CI, -0.15 to 1.03). The time to review a case averaged 5.20 minutes for WSI and 4.95 minutes for glass slides. There was no specific subset of diagnostic category that showed higher rates of modality-specific discrepancy, though some categories showed greater discrepancy than others in both modalities.
Conclusions.—:
WSIs are noninferior to traditional glass slides for primary diagnosis in anatomic pathology.
More Related Videos
10:57Real-Time, Two-Color Stimulated Raman Scattering Imaging of Mouse Brain for Tissue Diagnosis
Published on: February 1, 2022
06:47Expanding the Comprehension of the Tumor Microenvironment using Mass Spectrometry Imaging of Formalin-Fixed and Paraffin-Embedded Tissue Samples
Published on: June 29, 2022
Related Concept Videos
Three-Dimensional Microscopy in Microbiology
Two-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Overview of Microscopy Techniques