Related Experiment Video
Updated: Dec 28, 2025

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Heparin-induced thrombocytopenia: Diagnostic challenges in intensive care patients especially with extracorporeal
Karina Althaus1, Andreas Straub2, Helene Häberle2
1Center for Clinical Transfusion Medicine, University of Tübingen, Tübingen, Germany; Transfusion Medicine, Medical Faculty of Tübingen, Tübingen, Germany.
Background:
Heparin-induced thrombocytopenia (HIT) is a serious drug induced reaction that may be associated with life threatening complications. Platelet-activating antibodies directed against platelet factor 4 (PF4)/heparin complexes cause the disease. The diagnosis of HIT is challenging, as thrombocytopenia is a frequent finding in intensive care (ICU) patient population, especially during extracorporeal membrane oxygenation.
Objective:
To investigate the performance of a diagnostic algorithm for HIT in ICU patients.
Methods:
ICU patients who developed thrombocytopenia or thrombosis under heparin treatment were included in this study. The pretest probability for HIT was estimated using the 4Ts-score and patient's sera were tested using two rapid immunoassays (RA) LFI-HIT and PaGIA (from Milenia Biotec and DiaMed), and within 72 h using the IgG enzyme immunoassay (EIA) from Hyphen and the heparin induced platelet activation assay (HIPA).
Results:
392 consecutive ICU patients with suspected HIT were enrolled in this study, of whom 83/392 (21.2%) patients had extracorporeal circulation. Sera from 120/392 (30.6%) and 98/392 (25.0%) patients revealed positive results in RA and IgG EIA, respectively. The HIPA test revealed heparin-dependent platelet activation in a total of 15/392 (3.8%) ICU patients (3 medical and 12 surgical patients). In addition, sera from 7 patients revealed indeterminate HIPA results, of whom 2 patients had a clinical course compatible with HIT.
Conclusions:
Data from our study confirm the high frequency of IgG PF4/heparin antibodies in ICU patients under unfractionated heparin and shows that the combination of 4Ts-score and RA does not reduce the laboratory overinvestigation for HIT in these patients.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Hemodialysis II: Procedure and Complications
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies