Related Experiment Video
Updated: Dec 28, 2025

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Automated Collection and Analysis of Infrared Thermograms for Measuring Eye and Cheek Temperatures in Calves
Gemma Lowe1,2, Brendan McCane3, Mhairi Sutherland4
1InterAg, Ruakura Research Centre, Hamilton 3214, New Zealand.
Abstract:
As the reliance upon automated systems in the livestock industry increases, technologies need to be developed which can be incorporated into these systems to monitor animal health and welfare. Infrared thermography (IRT) is one such technology that has been used for monitoring animal health and welfare and, through automation, has the potential to be integrated into automated systems on-farm. This study reports on an automated system for collecting thermal infrared images of calves and on the development and validation of an algorithm capable of automatically detecting and analysing the eye and cheek regions from those images. Thermal infrared images were collected using an infrared camera integrated into an automated calf feeder. Images were analysed automatically using an algorithm developed to determine the maximum eye and cheek (3 × 3-pixel and 9 × 9-pixel areas) temperatures in a given image. Additionally, the algorithm determined the maximum temperature of the entire image (image maximum temperature). In order to validate the algorithm, a subset of 350 images analysed using the algorithm were also analysed manually. Images analysed using the algorithm were highly correlated with manually analysed images for maximum image (R2 = 1.00), eye (R2 = 0.99), cheek 3 × 3-pixel (R2 = 0.85) and cheek 9 × 9-pixel (R2 = 0.90) temperatures. These findings demonstrate the algorithm to be a suitable method of analysing the eye and cheek regions from thermal infrared images. Validated as a suitable method for automatically detecting and analysing the eye and cheek regions from thermal infrared images, the integration of IRT into automated on-farm systems has the potential to be implemented as an automated method of monitoring calf health and welfare.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

