Headspace gas chromatography for the determination of volatile methylsiloxanes in personal care products
Juan Aspromonte1, Giulia Giacoppo1,2, Kris Wolfs1
1Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven - University of Leuven, Herestraat 49, O&N2, PB 923, 3000, Leuven, Belgium.
Abstract:
Most of the reported methods for the analysis of volatile methylsiloxanes focus on their environmental fate or possible health effects, aiming at trace level analysis by using direct injection gas chromatography. However, system contamination as carry over and side reactions at the injector are commonly reported in those cases. In this article, we explore the use of headspace gas chromatography combined with the total vaporization technique as an alternative to avoid such issues for the analysis of linear (L2-L5) and cyclic (D3-D5) volatile methylsiloxanes. The proposed method showed good linearity with R2 values higher than 0.9961 and no significant contribution (α = 0.05) of the intercept. The limit of detection was always below 0.11 μg/vial (0.0025% m/m). Finally, the method was applied to real samples like an adhesive remover, hair oil, shampoo, and cream. After simple sample pretreatment, recoveries higher than 86% were achieved. Graphical abstract.
More Related Videos
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Volatilization