Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Non-targeted discovery-based analysis for gas chromatography with mass spectrometry: A comparison of peak table,
Chris E Freye1, Patrick R Bowden1, Margo T Greenfield1
1Los Alamos National Laboratory, M-7, High Explosives Science and Technology, Los Alamos, NM, 87545, USA.
Abstract:
The ability to discover minute differences between samples or sample classes for gas chromatography coupled to mass spectrometry (GC-MS) can be a challenging endeavor, especially when those differences are not a priori. Fisher ratio (F-ratio) analysis is an apt technique to probe the differences between GC-MS chromatograms. F-ratio analysis is a supervised, non-targeted, discovery-based method that compares two different samples (or sample classes) to reduce the GC-MS dataset into a hit list composed of class distinguishing compounds. Three different F-ratio techniques, peak table, tile, and pixel-based were used to "discover" nine non-native analytes that were spiked into gasoline at four different nominal concentrations of 250, 85, 25, 5 parts-per-million (ppm). For the tile and pixel-based F-ratio calculations, a novel methodology is introduced to improve the sensitivity of the F-ratio calculations while reducing false positives. Furthermore, we use a combinatorial technique using null class comparisons, termed null distribution analysis, to determine a statistical F-ratio cutoff for analysis of the hit lists. The pixel-based algorithm was the most sensitive method and was able to "discover" all nine spiked analytes at a nominal concentration of 250 ppm albeit with one false positive interspersed towards the bottom of the hit list. The pixel-based software was also able to "discover" more of the spiked analytes at the lower concentrations with seven of the spiked analytes "discovered" at 85 ppm, four of the spiked analytes "discovered" at 25 ppm, and one analyte "discovered" at 5 ppm.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...