Related Experiment Video
Updated: Dec 28, 2025

Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Automatic detection of anatomical landmarks of the aorta in CTA images
Pablo G Tahoces1, Daniel Santana-Cedrés2, Luis Alvarez2
1Department Electronics and Computer Science, University of Santiago de Compostela, Santiago de Compostela, Spain. pablo.tahoces@usc.es.
Abstract:
Computed tomography angiography (CTA) is one of the most common vascular imaging modalities. However, for clinical use, it still requires laborious manual analysis. This study demonstrates the feasibility of a fully automated technology for the accurate detection and identification of several anatomical reference points (landmarks), commonly used in intravascular imaging. This technology uses two different approaches, specially designed for the detection of aortic root and supra-aortic and visceral branches. In order to adjust the parameters of the developed algorithms, a total of 33 computed tomography scans with different types of pathologies were selected. Furthermore, a total of 30 independently selected computed tomography scans were used to assess their performance. Accuracy was evaluated by comparing the locations of reference points manually marked by human experts with those that were automatically detected. For supra-aortic and visceral branches detection, average values of 91.8 % for recall and 98.8 % for precision were obtained. For aortic root detection, the average difference between the positions marked by the experts and those detected by the computer was 5.7 ± 7.3 mm. Finally, diameters and lengths of the aorta were measured at different locations related to the extracted landmarks. Those measurements agreed with the values reported by the literature. Graphical abstract Schematic description of the proposed algorithm. The input includes an already segmented aorta (left), there are two main sub-processes related to the detection of branches and roots (center), and the output includes the segmented original aorta with the branches and the detected landmarks superimposed (right).
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:08Ultrasound Imaging of the Thoracic and Abdominal Aorta in Mice to Determine Aneurysm Dimensions
Published on: March 8, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT