Related Experiment Video
Updated: Dec 28, 2025

State of the Art Cranial Ultrasound Imaging in Neonates
Published on: February 2, 2015
An Evaluation of Image Acquisition Techniques, Radiographic Practice, and Technical Quality in Neonatal Chest
Christina Carøe Ejlskov Pedersen1, Maryann Hardy2, Anne Dorte Blankholm3
1Department of Radiology, Aarhus University Hospital, Aarhus, Denmark; Research Centre for Emergency Medicine, The research programme "The acute care patient", Aarhus University and Aarhus University Hospital, Aarhus, Denmark.
Background:
Neonatal chest radiography is a frequently performed diagnostic examination, particularly in preterm infants where anatomical and/or biochemical immaturity impacts on respiratory function. However, the quality of neonatal radiographic images has been criticized internationally and a prevailing concern has been that radiographers (radiologic technologists) fail to appreciate the unique nature of neonatal and infant anatomical proportions. The aim of this study was to undertake a retrospective evaluation of neonatal chest radiography image acquisition techniques against key technical criteria.
Methods:
One hundred neonatal chest radiographs, randomly selected from those acquired in 2014, were retrospectively evaluated. Inclusion criteria for radiograph were as follows: anterior-posterior supine; within 30 days of birth; and with all preprocessed collimation boundaries visible. Image evaluation was systematically undertaken using an image assessment tool. To test for statistical significance, Student's t-test, χ2 test, and logistic regression were undertaken.
Results:
Only 47% of the radiographs were considered straight in both upper and lower thoraces. The cranial collimation border extended beyond the upper border of the third cervical vertebra in 30% of cases, and the caudal border extended below the lower border of the first lumbar vertebra in 20% of cases, suggesting high possibility of neonatal overirradiation. Upper thorax rotation was significantly associated with head position (χ2 = 10.907; P < .001) as has been stated in many published textbooks internationally, but arm position had no apparent influence on rotation of the upper thorax (χ2 = 5.1260; P = .275). Birth weight was associated with accurate midline centering of central ray (logistic regression; OR = 1.0005; P = .009; CI, 1.00139-1.000957) with greater accuracy observed in images of neonates with higher birth weight.
Conclusion:
This study has highlighted areas for neonatal chest radiography improvement. Importantly, the findings bring into question commonly advocated radiographic techniques relating to arm positioning and assessment of rotation while confirming the importance of other technical factors. These findings begin the work toward developing the evidence base to underpin neonatal chest radiograph acquisition, but further prospective work and multicenter/multinational data comparison are required to confirm the findings.
More Related Videos
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...