Comparison of visual quality after Femto-LASIK and TransPRK in patients with low and moderate myopia
Jingjing Jiang1, Vishal Jhanji2, Lixia Sun1
1Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong, Dong Xia North Road, Shantou, Guangdong Province, China.
Purpose:
To compare the visual quality after surgery of femtosecond-assisted laser in situ keratomileusis (Femto-LASIK) and transepithelial photorefractive keratectomy (TransPRK) in low and moderate myopia patients.
Methods:
A prospective controlled study was performed on 114 eyes of 62 patients with low to moderate myopia, including 64 eyes of 36 cases in Femto-LASIK group and 50 eyes of 26 cases in TransPRK group. The uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), residual spherical equivalent (SE), wavefront aberration and contrast sensitivity were examined and analyses preoperatively, 1 month and 3 months postoperatively.
Results:
The UCVA over 0.8 was 100% in two groups at 1 month and 3 months postoperatively. Femto-LASIK group (96.49%) had a higher percentage than TransPRK group (67.39%) of UCVA over 1.0 at 1 month postoperatively (p < 0.001), but it was similar in two groups (97.78%, 90.48%) at 3 months postoperatively (p = 0.15). Femto-LASIK group (77.19%, 86.67%) had a higher percentage than TransPRK group (30.43%, 52.38%) of UCVA over 1.2 at 1 month and 3 months postoperatively (p < 0.001, p = 0.001). The SE of Femto-LASIK group was 0.07 ± 0.21 D, 0.02 ± 0.23 D at 1 month and 3 months postoperatively, and of TransPRK group was 0.11 ± 0.31 D, 0.14 ± 0.38 D; two groups had no significant differences (p = 0.57, p = 0.08). The safety index was 2.0 in Femto-LASIK group and 1.6 in TransPRK, while the efficacy index was 1.67 and 0.4, respectively. The vertical coma, spherical and higher-order aberrations of Femto-LASIK group were 0.37 ± 0.54 μm, 0.31 ± 0.27 μm, 0.89 ± 0.49 μm at 1 month postoperatively, and of TransPRK group were 0.12 ± 0.38 μm, 0.14 ± 0.28 μm, 0.71 ± 0.26 μm. There was significant difference between two groups at 1 months postoperatively (p < 0.001, p = 0.001, p = 0.006), but no significant difference at 3 months (p > 0.05). The contrast sensitivity without glare in 18 c/d spatial frequencies of Femto-LASIK group was 1.08 ± 0.26 at 1 month postoperatively, and that in TransPRK group was 0.99 ± 0.22. There was significant difference between two groups (p = 0.02). The contrast sensitivity with glare in 12 c/d and 18 c/d spatial frequencies at 1 month postoperatively had significant differences between Femto-LASIK and TransPRK groups (1.52 ± 0.17, 1.10 ± 0.23 vs 1.38 ± 0.39, 1.00 ± 0.27, p = 0.02, p = 0.03). While there were no significant differences at 3 months postoperatively (p > 0.05).
Conclusion:
Femto-LASIK had a higher increase in whole eye higher-order aberrations and contrast sensitivity than TransPRK at 1 month postoperatively, but they were similar at 3 months postoperatively in low and moderate myopia patients.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Glaucoma: Overview