Related Experiment Video
Updated: Dec 28, 2025

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
The modified Allen test and a novel objective screening algorithm for hand collateral circulation using differential
Ahmed Elwali1, Zahra Moussavi1,2
1Biomedical Engineering Program, University of Manitoba, Winnipeg, Canada.
Hand-ischemia and artery-thrombosis are serious complications of hand artery cannulation/grafting. Screening the patency of hand arteries reduces the complications. Modified Allen Test (MAT), Barbeau's test, and Doppler/Duplex-ultrasonic test screen hand arterial patency. Each of them, however, either lacks objectivity, requires subject cooperation, or is not readily available in operating rooms. In this pilot study, we aim to provide a novel, objective, reliable, and inexpensive alternative using differential photo-plethysmography (PPG) measurement, and an artery selection algorithm. For 11 participants, MAT was executed, and PPG measurements of the thumb and little fingers were recorded for left and right hands separately. For each hand, four evaluations were conducted, then fed into the artery selection algorithm. Our proposed procedure has shown congruent results with the anatomy of blood circulation. It identified two arteries in two participants causing >50% blood reduction in the hand due to their occlusion. It also showed an elevated risk of accessing an artery in another 8 participants. Once the results of this study are confirmed in larger samples, the proposed procedure/algorithm may provide many indicators of the hand blood circulation, the effect of an artery occlusion on the hand, and a recommendation for selecting the best artery to access with the lowest possible complications.
Hand-ischemia and artery-thrombosis are serious complications of hand artery cannulation/grafting. Screening the patency of hand arteries reduces the complications. Modified Allen Test (MAT), Barbeau's test, and Doppler/Duplex-ultrasonic test screen hand arterial patency. Each of them, however, either lacks objectivity, requires subject cooperation, or is not readily available in operating rooms. In this pilot study, we aim to provide a novel, objective, reliable, and inexpensive alternative using differential photo-plethysmography (PPG) measurement, and an artery selection algorithm. For 11 participants, MAT was executed, and PPG measurements of the thumb and little fingers were recorded for left and right hands separately. For each hand, four evaluations were conducted, then fed into the artery selection algorithm. Our proposed procedure has shown congruent results with the anatomy of blood circulation. It identified two arteries in two participants causing >50% blood reduction in the hand due to their occlusion. It also showed an elevated risk of accessing an artery in another 8 participants. Once the results of this study are confirmed in larger samples, the proposed procedure/algorithm may provide many indicators of the hand blood circulation, the effect of an artery occlusion on the hand, and a recommendation for selecting the best artery to access with the lowest possible complications.
More Related Videos
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation