Related Experiment Video
Updated: Dec 28, 2025

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Endobronchial ultrasound-guided transbronchial fine needle aspiration: Determinants of adequacy
Dilek Ece1, Sevinç Hallaç Keser1, Benan Çağlayan2
1Department of Pathology, Dr. Lütfi Kırdar Kartal Training and Research Hospital, İstanbul, Turkey.
Background:
This study aims to evaluate the factors influencing the adequacy of endobronchial ultrasound-guided transbronchial fine needle aspiration specimens.
Methods:
A retrospective analysis of 1,700 endobronchial ultrasound-guided transbronchial fine needle aspiration samples obtained from 822 patients (500 males, 322 females; mean age 56±13 years; range 16 to 83 years) was performed between March 2011 and March 2014 at our center. Variables potentially associated with sampling adequacy, such as all cytological materials and procedure notes (lymph node and/or lesion size, localization, needle pass number, and slide number) were examined.
Results:
The overall specimen adequacy was 79.8%. The specimen adequacy was associated with needle pass number (p≤0.001). Adequacy rate was 66.9% for one needle pass and 85.8% for three needle passes. According to the sampling regions, adequacy rates showed a difference [69.2%-85.8%; (p≤0.005)]. In the multivariate logistic regression analysis of subcarinal (7) lymph node station, patient age (odds ratio, 0.983; 95% confidence interval, 0.966-1.000; p=0.049) and number of slides (odds ratio, 1.240; 95% confidence interval, 1.062-1.448; p=0.006) were independent determining factors of specimen adequacy. While independent determinants of specimen adequacy for the right paratracheal (4R) region were lymph node size (odds ratio, 1.486; 95% confidence interval, 0.973-2.268; p=0.067) and number of slides (odds ratio, 1.418; 95% confidence interval, 1.146-1.756; p=0.001), they were lymph node size (odds ratio, 1.594; 95% confidence interval, 0.960-2.645; p=0.071) and number of needle passes (odds ratio, 2.277; 95% confidence interval, 1.360-3.811; p=0.002) for the right interlobar (11R) region. Independent determinant of specimen adequacy for the left paratracheal (4L) lymph node station was the number of needle passes (odds ratio, 1.656; 95% confidence interval, 0.955-2.869; p=0.072).
Conclusion:
During endobronchial ultrasound-guided transbronchial fine needle aspirations, particularly when rapid on site evaluation cannot be applied, consideration of factors affecting adequacy according to lymph node localizations may increase the chance for obtaining materials with suitable quality for cytologic evaluation.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...