Related Experiment Video
Updated: Dec 28, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
A comparative evaluation of resin- and varnish-based surface protective agents on glass ionomer cement - a
Shreya Tyagi1, Abi M Thomas1, Neeta Devi Sinnappah-Kang2
1Department of Pedodontics and Preventive Dentistry, Christian Dental College, Ludhiana, India.
Abstract:
Objectives: To evaluate and compare the effectiveness of resin- and varnish-based surface protective agents on Glass Ionomer Cement (GIC). The different surface protective agents used were: Vaseline®, GC Fuji VARNISH™ (varnish), G-Coat Plus™ (resin) and EQUIA® Coat (resin). Method: Thirty-six identical specimens of GIC were made. Six specimens were used in preparation of standard solution and remaining thirty were divided into five groups with six specimens in each group. Each test specimen was coated with one of the surface protecting agent except for the control group. The specimens were immersed separately into 1 ml of 0.05% methylene blue solution for 24 h and then rinsed with deionised water and further immersed into tubes containing 1 ml of 65% nitric acid. Specimens, once completely dissolved in nitric acid solution, were filtered and centrifuged. The supernatant was used to determine the absorbance using a spectrophotometer. The effectiveness of the surface protecting agents for the GIC was recorded in micrograms of dye per specimen, where low values indicate good protection. Result: Tukey HSD test revealed that GC Fuji VARNISH™ (varnish; mean = 21.25 µg/ml), G-Coat Plus™ (resin; mean = 30.39 µg/ml) and EQUIA® Coat (resin; mean = 9.32 µg/ml) were statistically not significantly different to each other and were effective in protecting the surface of GIC. Significance: The study found that there was a statistically significant difference between control and GC Fuji VARNISH™, G-Coat Plus™ and EQUIA® Coat. The three agents were found to be equally effective in protecting the surface of GIC.
Related Concept Videos
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectrometers
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...