Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
Related Experiment Video
Updated: Dec 28, 2025

The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Gopal Panta1, Ann K Richardson2, Ian C Shaw3
1School of Health Sciences, University of Canterbury, Christchurch, New Zealand. gopalpanta12@gmail.com.
Abstract:
Medical devices are sterilized before being used for invasive clinical procedures such as surgery, to prevent pathogen transfer. Failure to sterilize medical devices properly presents a risk of healthcare-associated infections. Studies and reports have indicated that inadequately sterilized medical devices are one of the causes of a higher rate of healthcare-associated infections in developing countries. Steam sterilization (autoclaving) is the most widely used method for sterilization and is considered the most robust and cost-effective method for sterilization of medical devices. The effectiveness of steam sterilization can be measured using biological indicators. A literature search was undertaken to understand the effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities across the globe. Studies using biological indicators for measuring the effectiveness of autoclaving were obtained. Failures of steam sterilization practices were identified and discussed as a means of identifying factors that might be associated with the ineffectiveness of steam sterilization practices between different countries. The number of studies measuring the effectiveness of steam sterilization is small, and few evaluate the effectiveness of steam sterilization specifically in developing countries. There are fewer studies on higher level healthcare facilities than dental facilities. More evidence about the effectiveness of autoclaving in healthcare facilities is needed to draw firm conclusions, but the data suggest that there are inadequacies in autoclave procedures and operator education.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Antimicrobial Effectiveness