Computed tomography has greatly improved over the last decade, especially through x-ray dose exposure reduction while maintaining image quality. Herein, a new concept is proposed to improve the contrast-to-noise ratio (CNR) by including the time-of-flight (TOF) information of individual photons to obtain further insight on the photon's trajectory and to reject scatter contribution. The proof of the concept relies on both simulation and experimental measurements in a cone-beam computed tomography arrangement. Results show a statistical difference between the TOF of scattered and primary photons exploitable in TOF computed tomography. For a large volume of the size of a human abdomen, a scatter reduction from 296% to 4% is achieved in our simulation setup with perfect timing measurements which yields a 110% better CNR, or a dose reduction by a factor of four. Cup artifacts are also reduced from 24.7% to 0.8%, and attenuation inaccuracies are improved from -26.3% to -0.8%. With 100 ps and 10 ps FWHM timing jitters, respectively 75% and 95% of the scatter contribution can be removed with marginal gains below 10 ps. Experimental measurements confirm the feasibility of measuring statistical differences between the TOF of scattered and primary photons.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...