Related Experiment Video
Updated: Dec 27, 2025

Author Spotlight: Tracking Electrochemistry on Single Nanoparticles with Surface-Enhanced Raman Scattering Spectroscopy and Microscopy
Published on: May 12, 2023
Voltammetric sensing of silver nanoparticles on electrodes modified with selective ligands by using covalent and
Juan C Vidal1, Darío Torrero2, Sonia Menés2
1Analytical Spectroscopy and Sensors Group (GEAS), Institute of Environmental Sciences (IUCA), University of Zaragoza, c/ Pedro Cerbuna, 12, 50009, Zaragoza, Spain. jcvidal@unizar.es.
Abstract:
New electrochemical sensors are described for the rapid quantification of silver nanoparticles (AgNPs). They are based on the immobilization of L-cysteine on a glassy carbon electrode (GCE) and on the formation of electropolymerized oligomers on the GCE. Ligands with amino, sulfur and carboxy functional groups are used that are capable of selectively retaining AgNPs. The experimental conditions for electropolymerizations were optimized for each of four monomers studied: L-lysine, thiophene-3-carboxamide, thionin, and o-phenylene-diamine. The best retention capabilities and conditions for quantification of AgNPs were found for immobilized nanoparticle voltammetry. This method is more sensitive than others based on the sorption of AgNPs from dispersions. These ligands also retain ionic silver species. Hence, Ag(I) and Ag0 can be discriminated, and the total silver content can be quantified by stripping voltammetry. The best analytical properties (for dispersions of AgNPs of 40 nm diameter) were found with GCEs carrying electropolymerized L-lysine. Figures of merit include (a) sensitivity of 4.329 ± 0.031 μA μg-1 mL cm-2, (b) a detection limit of 0.010 μg mL-1, and (c) a relative standars deviation of about 7.2% (for n = 4). The poly-L-lysine sensors can also evaluate the size of the AgNPs in the range 20 to 80 nm diameter, owing to displacements of the maximum potential of the voltammetry peaks. Graphical abstractSchematic representation of the quantification of silver nanoparticles (AgNPs) with a glassy-carbon electrode (GCE) modified with electropolymerized poly(L-lysine). AgNPs (and Ag+ ions) are selectively preconcentrated in the polymer and determined by differential-pulse stripping voltammetry.
More Related Videos
07:23Fabrication of Thin Film Silver/Silver Chloride Electrodes with Finely Controlled Single Layer Silver Chloride
Published on: July 1, 2020
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Pulse Voltammetry