Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Radiographic Image Radiomics Feature Reproducibility: A Preliminary Study on the Impact of Field Size
Sajjad Rastegar1, Jalal Beigi1, Ehsan Saeedi1
1Student Research Committee, Paramedical Faculty, Rafsanjan University of Medical Sciences, Rafsanjan, Iran; Department of Radiology Technology, Paramedical Faculty, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
Rationale And Objectives:
Radiomics is an approach to quantifying diseases. Recently, several studies have indicated that radiomics features are vulnerable against imaging parameters. The aim of this study is to assess how radiomics features change with radiographic field sizes, positions in the field size, and mAs.
Materials And Methods:
A large and small wood phantom and a cotton phantom were prepared and imaged in different field sizes, mAs, and placement in the radiographic field size. A region of interest was drawn on the image features, and twenty two features were extracted. Radiomics feature reproducibility was obtained based on coefficient of variation, Bland-Altman analysis, and intraclass correlation coefficient. Features with coefficient of variation ≤ 5%, intraclass correlation coefficient ≤ 90%, and 1% ≤ U/LRL ≤30% were introduced as robust features. U/LRL is upper/lower reproducibility limits in Bland-Altman.
Results:
For all field sizes and all phantoms, features including Difference Variance, Inverse Different Moment, Fraction, Long Run Emphasis, Run Length Non Uniformity, and Short Run Emphasis were found as highly reproducible features. For change in the position of field size, Fraction was the most reproducible in all field sizes and all phantoms. On the mAs change, we found that feature, Short Run Emphasis field 15 × 15 for small wood phantom, and Correlation in all field sizes for Cotton are the most reproducible features.
Conclusion:
We demonstrated that radiomics features are strongly vulnerable against radiographic field size, positions in the radiation field, mAs, and phantom materials, and reproducibility analyses should be performed before each radiomics study. Moreover, these changing parameters should be considered, and their effects should be minimized in future radiomics studies.