Related Experiment Video
Updated: Dec 27, 2025

05:57
Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
8.2K
A Doppler ghost in the pulmonary artery.
Kumral Cagli1, Nilgun Isıksalan Ozbulbul2, Ozcan Ozeke1
1Department of Cardiology, Ankara City Hospital, Ankara, Turkey.
Echocardiography (Mount Kisco, N.Y.)
|February 25, 2020
Summary
Patent ductus arteriosus (PDA) can lead to Eisenmenger syndrome. This case highlights reversed PDA diagnosed via echocardiography, Doppler, and CT, causing pulmonary hypertension.
Area of Science:
- Cardiology
- Pulmonology
- Medical Imaging
Background:
- Patent ductus arteriosus (PDA) is a congenital heart defect where the ductus arteriosus fails to close after birth.
- Left-to-right shunting through a PDA can lead to pulmonary hypertension and, in advanced cases, Eisenmenger syndrome.
Observation:
- A 27-year-old female presented with symptoms of pulmonary hypertension.
- Echocardiography revealed findings suggestive of a reversed PDA, with Doppler studies of the pulmonary artery indicating reversed flow.
Findings:
- The diagnosis of reversed PDA as the cause of pulmonary hypertension was confirmed.
- Contrast study and computed tomography (CT) provided definitive imaging confirmation.
Implications:
- This case underscores the importance of considering reversed PDA in the differential diagnosis of pulmonary hypertension.
- Accurate diagnosis through advanced imaging techniques like echocardiography and CT is crucial for appropriate management.
Related Concept Videos
Doppler Effect - II
4.3K
The Doppler effect has several practical, real-world applications. For instance, meteorologists use Doppler radars to interpret weather events based on the Doppler effect. Typically, a transmitter emits radio waves at a specific frequency toward the sky from a weather station. The radio waves bounce off the clouds and precipitation and travel back to the weather station. The radio frequency of the waves reflected back to the station appears to decrease if the clouds or precipitation are moving...
4.3K
Assessing Blood pressure using a doppler ultrasound
2.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.2K
Equipments Used To Measure Blood Pressure
2.9K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.9K
Doppler Effect - I
5.9K
The Doppler effect and Doppler shift were named after the Austrian physicist and mathematician Christian Johann Doppler in 1842, who conducted experiments with both moving sources and moving observers. Consider an observer standing on a street corner, observing an ambulance with a siren sound passing by at a constant speed. The observer experiences two characteristic changes in the sound of the siren. Initially, the sound increases in loudness as the ambulance approaches and decreases in...
5.9K
Cardiovascular System Abnormal Findings II: Auscultation
460
Auscultation, an essential part of a heart examination, is done using a stethoscope. It provides crucial information about heart function and possible heart problems. Due to heart problems, abnormal sounds can be heard during systole or diastole. These sounds include S3 and S4 gallops, opening snaps, systolic clicks, and murmurs.
Abnormal Heart Sounds
Gallops:
Abnormal Heart Sounds
Gallops:
460
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
316
Aortic valve regurgitation (AR) occurs when the aortic valve fails to close properly, allowing blood to flow backward from the aorta into the left ventricle. This backflow can result in two distinct clinical presentations: acute and chronic AR, each characterized by its own set of symptoms and physical findings.Acute Aortic RegurgitationAcute AR presents with a sudden onset of severe symptoms. Patients typically experience profound dyspnea (shortness of breath), chest pain, and signs of left...
316

