Related Experiment Video
Updated: Dec 27, 2025

Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Improvements in National Code Red transfusion practice in Scotland after adoption of recommendations from the
Matthew J Reed1, Claire Cooke2, Niall McMahon3
1Department of Emergency Medicine, Royal Infirmary of Edinburgh, NHS Lothian, 51 Little France Crescent, Edinburgh, EH16 4SA, United Kingdom; Emergency Medicine Research Group Edinburgh (EMERGE), Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh, EH16 4SA, United Kingdom; Edinburgh Acute Care, Usher Institute of Population Health Sciences and Informatics, College of Medicine and Veterinary Medicine, University of Edinburgh, Edinburgh, United Kingdom.
Aims:
The Scottish Transfusion and Laboratory Support in Trauma Group (TLSTG) previously reviewed all National Code Red activations between June 1st 2013 and October 31st 2015, generating a number of recommendations to be adopted to optimise the transfusion support given to patients following major trauma in Scotland. A repeat National survey was undertaken for all patients for whom Code Red was activated between 1st November 2015 and 31st December 2017.
Methods:
A clinical and transfusion lead for each centre entered anonymised data onto a secure electronic database (REDCap).
Results:
During the study period there were 66 activations (24 South-East of Scotland, 32 West, 10 East). Mean age was 45 years and 88% were male. Mean Injury Severity Score (ISS) was 28 with 75% blunt trauma. 93% (62/66) of Code Red patients received blood components with a 300% increase in pre-hospital transfusion (48 vs 16 patients; p<0.001). Median time from 999 call to Code Red activation reduced significantly to 37 min from 70 min (p = 0.01) giving the hospital more time to prepare transfusion components. 78% patients received pre-hospital tranexamic acid (TXA; improved from 70%, p = 0.67, ns). Concentrated Red Cell (CRC): Fresh Frozen Plasma (FFP) ratio was always less than 2:1 and below 1.4:1 at 90 min, compared to 2013-15 when CRC: FFP ratios did not drop to below 2:1 until 150 min after arrival in the ED. Mean time for Full Blood Count (FBC; 46 mins versus 81; p = 0.004) and clotting (53 mins versus 119; p<0.001) result was reduced. Survival to hospital discharge was unchanged (66% versus 63%; p = 1.00 ns).
Conclusions:
Code Red practice has improved in several ways since our last survey with earlier Code Red activation, more patients receiving pre-hospital transfusion and improved CRC:FFP ratios. Interventions such as earlier on scene Code Red activation, provision of pre-hospital TXA, Emergency Department (ED) resuscitation room pre-thawed FFP and point-of-care viscoelastic coagulation testing have all contributed to these improvements in transfusion practice in Scotland.
More Related Videos
07:24A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
09:54Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Related Concept Videos
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Rh Blood Group
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Bone Marrow Sampling and Transplants
The transplant begins with high doses of chemotherapy and radiation treatment, which aim to destroy...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...