Comparative study between pSWE and 2D-SWE techniques integrated in the same ultrasound machine, with Transient Elastography as the reference method
Related Experiment Video
Updated: Dec 27, 2025

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Camelia Gianina Foncea1, Alina Popescu2, Raluca Lupusoru3
1Department of Gastroenterology and Hepatology, Victor Babes University of Medicine and Pharmacy Timişoara, Romania. Foncea.camelia@gmail.com.
Aim:
To evaluate the feasibility of two elastographic methods, point Shear Wave Elastography (pSWE) and two dimensional Shear Wave Elastography (2D-SWE), integrated in the same ultrasound machine, for liver fibrosis (LF) assessment, using Transient Elastography (TE) as the reference method.
Material And Methods:
We included in the study 115 subjects in which LF was evaluated in the same session by TE (FibroScan, EchoSens), pSWE and 2D-SWE (Samsung-Medison RS85). Reliable liver stiffness (LS) measurements were defined: for TE the median value of 10 measurements with interquartile range (IQR/M)≤30%,while for pSWE and 2D-SWE the median value of 10 measurements, with a reliability measurement index (RMI)≥0.5 and IQR/M≤30%. For classification of LF severity we used TE as the reference method with the following cut-offs: F2≥7kPa, F3≥9.5kPa and F4≥12kPa.
Results:
Reliable measurements by TE were obtained in 98.2% of cases (113/115), by pSWE in 93.9% of cases (108/115) and by 2D-SWE in 92.1% of cases (106/115), so the final analysis included 101 patients. We divided the cohort into 3 groups: fibrosis 5.9 kPa [AUROC=0.95, 95%CI(0.89;0.98), p<0.0001, Se=94.1%, Sp=89.5%, PPV=82.1%, NPV=96.8%]; F4 LS >8 kPa [AUROC=0.98, 95%CI(0.94;0.99), p<0.0001, Se=94.4%, Sp=95.1%, PPV=81%, NPV=98.7%], while for 2D-SWE they were: F≥2 LS >6.1 kPa [AUROC=0.93, 95%CI(0.86;0.97), p<0.0001, Se=91.1%, Sp=80.6%, PPV=70.5%, NPV=94.7%]; F4 LS >7.6 kPa [AUROC=0.98, 95%CI(0.93;0.99), p<0.0001, Se=100%, Sp=91.5%, PPV=72%, NPV=100%]. We observed strong correlations between LS values obtained by TE and 2D-SWE (r=0.85), between TE and pSWE (r=0.88) and between pSWE and 2D-SWE (r=0.90) (p=0.37), respectively. There were no significant differences between the mean values obtained by pSWE and 2D-SWE (p=0.96).
Conclusion:
The pSWE and 2D-SWE are feasible methods for assessing liver fibrosis, both techniques strongly correlating with TE results.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...