Related Experiment Video
Updated: Dec 27, 2025

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Evaluation of the three methods of bacterial decontamination on implants with three different surfaces
Paweł Kubasiewicz-Ross1, Małgorzata Fleischer2, Artur Pitułaj1
1Department of Oral Surgery, Wroclaw Medical University, Poland.
Background:
The main goal of the treatment of the peri-implantitis is to decontaminate the surface of the implant, thereby enabling further treatment involving, e.g., guided bone regeneration. Since new implants of the rougher surface were introduced to the common dental practice, decontamination is even more difficult.
Objectives:
The aim of the study was to evaluate 3 different methods of decontaminating implants with 3 different surfaces.
Material And Methods:
A total of 30 dental implants with 3 different surface types (machined, sandblasted, and acid-etched (SLA) and hydroxyapatite (HA)-coated) were used in the study. Each group of implants was coated with Escherichia coli biofilm and cultivated. Afterwards, the implants were transferred to the jaw model and treated with a different method: sonic scaler mechanical debridement with a Woodpecker PT5 sonic scaler (1st group), and mechanical debridement with sonic scaler and with the combination with chemical agent Perisolv® (2nd group), and with Er:YAG laser treatment (3rd group). Each implant was treated with the specific method and sent for further microbiological evaluation.
Results:
The highest level of decontamination was achieved for machined-surface implants and the lowest for HA-coated implants. The method with the highest biofilm reduction was the scaler and Perisolv® group. The highest level of decontamination of HA-coated implants were achieved for Er:YAG laser irradiation method.
Conclusions:
In the following paper, the superiority of combined chemical-mechanical method of decontaminating the surface of the implant on SLA and machined-surface implants was proved. On the contrary, Er:YAG laser irradiation was reported as the best option for decontamination of the HA-coated implants. In our opinion, it is a significant finding, revealing that the method of peri-implantitis management should be considered in accordance to the type of the surface of the implant (customized to the surface of the implant).
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Bacterial Signaling
Antimicrobial Effectiveness
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...