Related Experiment Video
Updated: Dec 27, 2025

Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
Published on: May 29, 2012
Monitor Ionizing Radiation-Induced Cellular Responses with Raman Spectroscopy, Non-Negative Matrix Factorization, and
Xinchen Deng1, Ramie Ali-Adeeb1, Jeffrey L Andrews2
1Department of Physics, I.K. Barber School of Arts and Sciences, The University of British Columbia, Kelowna, Canada.
Abstract:
Radiation therapy (RT) is one of the most commonly prescribed cancer treatments. New tools that can accurately monitor and evaluate individual patient responses would be a major advantage and lend to the implementation of personalized treatment plans. In this study, Raman spectroscopy (RS) was applied to examine radiation-induced cellular responses in H460, MCF7, and LNCaP cancer cell lines across different dose levels and times post-irradiation. Previous Raman data analysis was conducted using principal component analysis (PCA), which showed the ability to extract biological information of glycogen. In the current studies, the use of non-negative matrix factorization (NMF) allowed for the discovery of multiplexed biological information, specifically uncovering glycogen-like and lipid-like component bases. The corresponding scores of glycogen and previously unidentified lipids revealed the content variations of these two chemicals in the cellular data. The NMF decomposed glycogen and lipid-like bases were able to separate the cancer cell lines into radiosensitive and radioresistant groups. A further lipid phenotype investigation was also attempted by applying non-negative least squares (NNLS) to the lipid-like bases decomposed individually from three cell lines. Qualitative differences found in lipid weights for each lipid-like basis suggest the lipid phenotype differences in the three tested cancer cell lines. Collectively, this study demonstrates that the application of NMF and NNLS on RS data analysis to monitor ionizing radiation-induced cellular responses can yield multiplexed biological information on bio-response to RT not revealed by conventional chemometric approaches.
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
07:37An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...