Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Dynamic pressure gradient modulation for comprehensive two-dimensional gas chromatography with time-of-flight mass
Sonia Schöneich1, Derrick V Gough1, Timothy J Trinklein1
1Department of Chemistry, University of Washington, Box 351700, Seattle, WA 98195, USA.
Abstract:
Dynamic pressure gradient modulation (DPGM) is investigated for comprehensive two-dimensional gas chromatography (GC × GC) with time-of-flight mass spectrometry (TOFMS) detection. With DPGM, a commercial pneumatic "pulse" valve is opened to introduce a suitably high auxiliary gas pressure at a T-junction connecting the first dimension (1D) and second dimension (2D) columns during the modulation period (PM), temporarily stopping the 1D flow. The valve is then closed for the duration of a pulse width (pw) to "re-inject" temporally focused 1D eluate onto the 2D column for separation. This flow modulation technique is observed to be compatible with TOFMS detection using a 2D flow rate of 4 ml/min for the separation of a 90-component test mixture. A 25 min separation window using a PM = 1 s and pw = 200 ms for full modulation (and 100% duty cycle) provided an average 1Wb = 4.5 s and 2Wb = 130 ms for a 2D peak capacity of nc,2D = 2700 (100 peaks per min). The detector response enhancement factor (DREF) serves as a metric for the enhanced sensitivity of the modulated relative to the unmodulated 1D peaks, with DREFs ranging between 10 and 20 and about a 5-fold improvement in signal-to-noise ratio (S/N). The bilinear "quality" of the GC × GC data is studied using the chemometric method parallel factor analysis (PARAFAC). Since PARAFAC requires sufficiently trilinear data, the reproducibility of the 2D peak shape for a given analyte is confirmed using lack-of-fit (LOF) and percent variation (R2) metrics. The limit-of-detection (LOD) for the representative analyte hexadecane is determined using PARAFAC, providing an LOD of 0.7 ppb (±0.03 ppb) for three replicates. Seven heavily overlapped analytes are also fully resolved by PARAFAC down to the part-per-million (ppm) concentration level, producing reproducible spectra with a majority of spectral match values (MV) over 800 (RSD ≤ 7.1%). This study provides promising results for DPGM as a flow modulation technique compatible with GC × GC-TOFMS, providing high sensitivity data suitable for chemometric analysis.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...