Variability in echocardiography and MRI for detection of cancer therapy cardiotoxicity
James Lambert1, Mariana Lamacie1, Babitha Thampinathan1
1Ted Rogers Program in Cardiotoxicity Prevention, Peter Munk Cardiac Center, Division of Cardiology, University Health Network, University of Toronto, Toronto, Ontario, Canada.
Objectives:
To compare variability of echocardiographic and cardiovascular magnetic resonance (CMR) measured left ventricular (LV) function parameters and their relationship to cancer therapeutics-related cardiac dysfunction (CTRCD).
Methods:
We prospectively recruited 60 participants (age: 49.8±11.6 years), 30 women with human epidermal growth factor receptor 2-positive breast cancer (15 with CTRCD and 15 without CTRCD) and 30 healthy volunteers. Patients were treated with anthracyclines and trastuzumab. Participants underwent three serial CMR (1.5T) and echocardiography studies at ~3-month intervals. Cine-CMR for LV ejection fraction (LVEF), myocardial tagging for global longitudinal strain (GLS) and global circumferential strain (GCS), two-dimensional (2D) echocardiography for strain and LVEF and three-dimensional (3D) echocardiography for LVEF measurements were obtained. Temporal, interobserver and intraobserver variability were calculated as the coefficient of variation and as the SE of the measurement (SEM). Minimal detected difference (MDD) was defined as 2xSEM.
Results:
Patients with CTRCD demonstrated larger mean temporal changes in all parameters compared with those without: 2D-LVEF: 4.6% versus 2.8%; 3D-LVEF: 5.2% vs 2.3%; CMR-LVEF: 6.6% versus 2.7%; 2D-GLS: 1.9% versus 0.7%, 2D-GCS: 2.5% versus 2.2%; CMR-GCS: 2.7% versus 1.6%; and CMR-GLS: 2.1% versus 1.4%, with overlap in 95% CI for 2D-LVEF, 2D-GCS, CMR-GLS and CMR-GCS. The respective mean temporal variability/MDD in healthy volunteers were 3.3%/6.5%, 1.8%/3.7%, 2.2%/4.4%, 0.8%/1.5%, 1.9%/3.7%, 1.8%/3.6% and 1.4%/2.8%. Although the mean temporal variability in healthy volunteers was lower than the mean temporal changes in CTRCD, at the individual level, 2D-GLS, 3D-LVEF and CMR-LVEF had the least overlap. 2D-GLS and CMR-LVEF had the lowest interobserver/intraobserver variabilities.
Conclusion:
Temporal changes in 3D-LVEF, 2D-GLS and CMR LVEF in patients with CTRCD had the least overlap with the variability in healthy volunteers; however, 2D-GLS appears to be the most suitable for clinical application in individual patients.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies