The use of a personal computer for trend data analysis with the Ohmeda 3700 pulse oximeter
1Department of Pediatrics and Child Health, University of Manitoba, Winnipeg, Canada.
Abstract:
The Ohmeda 3700 pulse oximeter provides trend data storage of arterial oxygen saturation (SaO2) and pulse rate measurements for a maximum of 8 hours. This feature allows the oximeter to be used as a stand-alone unit for overnight studies of saturation during sleep. Subsequent transfer and processing of the stored SaO2 data requires additional software. We present a program for data processing that uses the Lotus 1-2-3 program on IBM and compatible microcomputers and that performs a data distribution and statistical analysis on these trend data and presents them in graphic form. Processing SaO2 trend data within the Lotus 1-2-3 worksheet format allows the user to easily add to or modify the program presented here, depending on individual needs.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...