Related Experiment Video
Updated: Aug 23, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement
E Y Cheng1, M B Hopwood, J Kay
1Department of Anesthesiology, Medical College of Wisconsin, Milwaukee 53226.
Abstract:
Usual monitoring sites for pulse oximetry involve the fingers, toes, ear lobe, and nasal septum. This study examined the performance of a forehead sensor compared with a finger sensor for the pulse oximeter and arterial blood gas (ABG) analysis. Ten healthy adult volunteers and 22 ventilator-dependent patients were studied. The arterial oxygen saturation detected by forehead pulse oximetry (SpO2) correlated well with finger SpO2 and arterial oxygen saturation (SaO2) determined by arterial blood gas analysis in the healthy volunteers. Forehead SpO2 in mechanically ventilated patients correlated well with finger SpO2 and SaO2 when heart rate detected by pulse oximeter differed less than 10% from apical heart rate. Factors that caused a difference in oximeter-detected heart rate and apical heart rate were extensive tissue edema, head movement, and difficulty securing good tape placement. This suggests that when signal strength is weak, causing poor pulse rate detection, there will also be problems associated with accurate SpO2. The forehead pulse oximeter sensor works well on healthy, well-oxygenated volunteers. Difficulty was experienced when applying and using the sensor on critically ill patients. The reliability of the forehead pulse oximeter sensor has not been established at low saturations.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...