Valet Parking for Protein Ion Charge State Concentration: Ion/Molecule Reactions in Linear Ion Traps

David J Foreman1, Jay S Bhanot1, Kenneth W Lee1

  • 1Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-2084, United States.

Analytical Chemistry
|February 27, 2020
PubMed

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.3K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
1.6K
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.3K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
1.9K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
769
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
1.1K