Related Experiment Video
Updated: Dec 27, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Refractive and Visual Outcomes After Bilateral Implantation of a Trifocal Intraocular Lens in a Large Population
Edgardo Carreño1, Edgardo A Carreño1, Rodrigo Carreño1
1Centro Oftalmológico Carreño, Las Condes, Santiago, Chile.
Purpose:
To review refractive, visual acuity, defocus curve and contrast sensitivity results after bilateral implantation of a trifocal intraocular lens (IOL) in a large population.
Setting:
One site in Santiago, Chile.
Design:
Single arm, non-randomized retrospective chart review.
Methods:
This was a single-arm retrospective chart review of clinical outcomes after bilateral implantation of a trifocal IOL (Panoptix®), both toric and non-toric versions. Binocular visual acuity at 4 m, 60 cm and 40 cm was tested. Other tests included refraction, mesopic and photopic contrast sensitivity, and defocus curve measurement.
Results:
The review included 500 eyes of 250 patients implanted with the trifocal IOL and 200 eyes of 100 patients implanted with the trifocal toric IOL, with no clinically significant differences between groups. Ninety-six percent of all eyes were within 0.50D of the intended spherical equivalent correction. In the toric group, 94% of eyes (187/200) had a residual refractive cylinder ≤0.50D, compared to 81% of eyes (406/500) in the non-toric group. Four out of five patients (80.6%, 282/350) had a binocular uncorrected VA of 0.1 logMAR (20/25) at all test distances. Mean defocus was 0.1 logMAR or better from vergences from 0.00 to -3.00 D (corresponding to vision from distance to about 33 cm). With a cutoff of 0.2 logMAR, 96% of patients had a range of vision 2.5 D or greater. Contrast sensitivity was similar between the toric and non-toric lenses, and similar to age-matched normal results.
Conclusion:
The non-toric and toric trifocal IOLs provided good distance, intermediate and near vision to patients, with a wide range of vision and good contrast sensitivity.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview