Abstract:
Pb2+ and Cd2+ are the most ubiquitous heavy metal ion pollutants, and they have aroused much attention due to their irreversible and significant damage to human organ. In this work, a new fluorescein-based "OR-AND" logic gate colorimetric probe 3',6'-bis((tert-butyldiphenylsilyl)oxy)-2-(2-((2-hydroxyphenyl)imino)ethylidene)aminspiro[isoindoline-1,9'-xanthen]-3-one (FP) was designed and synthesized via attaching 2-(2-((2-hydroxyphenyl)imino)ethylidene)amino and tert-butyldiphenylsilyl to fluorescein as the specific identification groups. This sensor can rapidly and sensitively discriminate Pb2+ and Cd2+ by utilizing F- as an auxiliary reagent. When Pb2+ or Cd2+ was added into the FP solution, the absorption band at 533 nm increased and the peak at 374 nm decreased, the color changed from colorless to pale-purple, resulting in a ratiometric spectral change. However, adding fluoride ion to the FP solution containing Pb2+ or Cd2+ resulted in a distinct phenomenon in which the pale purple color fades out to colorless for a Pb2+-containing solution and deepen to dark purple for a Cd2+-containing solution, which is attributable to the different coordination mechanisms. In aqueous solution, the detection limits of FP can reach 0.42 μM for Pb2+ and 0.53 μM for Cd2+. The probe exhibited rapid responses for these analytes. Moreover, FP was successfully used to rapidly detect trace amounts of hazardous Pb2+ and Cd2+ in tap water with good relative recovery and the relative standard deviations (RSD) were 1.8% for Pb2+ and 0.3% for Cd2+, providing a novel approach for detecting Pb2+ and Cd2+ in practical application.
More Related Videos
09:30Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...