Related Experiment Video
Updated: Dec 27, 2025

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Post-column detection of cadmium chelators by high-performance liquid chromatography using
Chia-Shang Chen1, Shinya Ogawa2, Yuki Imura1
1Department of Applied Biological Chemistry, Graduate School of Agricultural and Life Sciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-8657, Japan.
Abstract:
Cd(II) is toxic to many species, including humans, because it inactivates a number of enzymes and induces cytopathic effects in the liver, kidney, and skeletal tissues in humans. Metallothionein and glutathione (GSH) play a major role in the protection against Cd(II)-induced toxicity in mammalian cells. In this study, a relatively simple method for detecting trace amounts of Cd(II) chelators was developed by using 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid (TPPS). The TPPS-Cd(II) complex was added to the elutions of high-performance liquid chromatography. The Cd(II) chelators separated by column chromatography were mixed with Cd(II)-bound TPPS (TPPS-Cd(II)). Cd(II) from TPPS-Cd(II) was chelated by the eluted Cd(II) chelators, resulting in the formation of free TPPS. The absorbance of TPPS shifted from 434 nm (TPPS-Cd(II)) to 414 nm (TPPS), and this characteristic shift was used to estimate the quantity and affinity of the Cd(II) chelators. This new method was compared with the bathocuproine disulfonate (BCS) method developed in our previous study. Instead of BCS-Cu(I), TPPS-Cd(II) was used as the colorimetric reagent. The experimental setup of the TPPS-based method is more general, and the preparation of the colorimetric solution is also much simpler than the BCS method. To verify the efficacy of this new method, we determined the actual Cd(II)-chelating ability of GSH in horse blood; the obtained concentration was in good agreement with the previously reported value.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Principles Of Column Chromatography