A wireless optical handheld device for carotid waveform measurement and its validation in a clinical study
Derek Rinderknecht1, Jules Moreau De Balasy1, Niema M Pahlevan2,3,4
1Avicena LLC, Pasadena, CA, United States of America.
Objective:
Here we introduce Vivio, a wireless optical tonometer, and compare its pulse waveform measurement capabilities to the AtCor SphygmoCor.
Approach:
Pulse waveform data from both devices was captured on a heterogeneous cohort of 29 participants (15 males, 14 females), including 16 healthy individuals free from cardiovascular diseases and 13 patients with one or more cardiovascular diseases. These participants were a subgroup of the Huntington Medical Research Institutes (HMRI) iPhone Heart Study. Main r esults: Carotid pulse waveforms captured by Vivio were comparable to those captured using the AtCor SphygmoCor tonometer. The point-by-point root-mean-square error between averaged waveforms captured by either device on the same participant was 6.3% with a standard deviation of 2%. The harmonic content of the pulse waveforms captured by either device was also similar. Data collected by Vivio displayed good to excellent agreement across a wide range of pulse waveform features such as left ventricular ejection time, reflected wave arrival time, the ratio of systolic to diastolic time intervals, and heart rate. A comparison between augmentation index (AI) measured by Vivio and tonometry showed a correlation of 0.82 (p < 0.01). Bland-Altman analysis of this data yielded a bias of -2.5% and limits of agreement spanning -15.1%-10.1%.
Significance:
The Vivio has the potential to enhance the availability of noninvasive pulse waveform data, thereby expanding the tools available for the diagnosis and monitoring of cardiovascular disease. When used in combination with advanced waveform analysis methods, Vivio can impact mobile healthcare resulting in improved patient health, quality of life and the overall reduction of healthcare costs.
More Related Videos
06:04Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)