Electrode Afterload: A Valuable Technique in a Case of Short Electrode Insertion
C Riemann1, S Scholz2, H Sudhoff1
1Department of Otolaryngology, Head and Neck Surgery, Bielefeld University, Klinikum Bielefeld, Campus Mitte, Bielefeld, Germany.
Case Reports in Otolaryngology
|February 29, 2020
Summary
Deeper cochlear implant electrode insertion during revision surgery can improve speech understanding without compromising residual hearing. This case demonstrates successful hearing preservation and enhanced speech perception through electrode afterloading.
Area of Science:
- Otolaryngology
- Neurosurgery
- Audiology
Background:
- Electrode position in the cochlea is crucial for speech performance.
- Factors like array length, insertion depth, and anatomy influence intracochlear electrode placement.
- Deep insertions (>20 mm) and revision surgeries pose risks to residual hearing and electrode integrity.
Observation:
- A 73-year-old female patient with hearing loss underwent multiple surgeries for cholesteatoma, followed by cochlear implant (CI) surgery.
- Poor speech understanding post-CI led to revision surgery, revealing the electrode's initial marker at 20 mm.
- The electrode was advanced an additional 4 mm deeper into the cochlea.
Findings:
- Speech perception improved significantly, reaching 25% at six months and 45% at twelve months post-revision, as measured by the Freiburger monosyllabic speech test.
- Hearing preservation was achieved despite the deeper insertion (to 24 mm).
- A partially obliterated open cavity facilitated surgical access for the deeper insertion.
Implications:
- Revisional deeper insertion of cochlear implant electrodes is feasible and can enhance speech understanding while preserving hearing.
- This technique challenges the assumption that deeper insertions inherently risk hearing loss.
- Careful surgical planning and execution are vital, especially in revision cases, to optimize outcomes and minimize iatrogenic risks.
Related Concept Videos
Electrogravimetric Analysis: Overview
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
Electrodeposition
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...