Efficacy and safety of traction-assisted endoscopic submucosal dissection: a meta-regression of randomized clinical
Ying-Fong Su1,2, Sheng-Wei Cheng3, Chun Chao Chang4,5
1School of Medicine, College of Medicine, Taipei Medical University, Taipei, Republic of China (Taiwan).
Background:
Endoscopic submucosal dissection (ESD) is widely used to treat gastrointestinal lesions. A traction-assisted (TA) strategy has been recently developed for ESD. In this study, we evaluated the safety and efficacy of TA-ESD compared with conventional ESD (C-ESD).
Methods:
We searched PubMed, Embase, Web of Science, and the China National Knowledge Infrastructure to identify randomized clinical trials that compared TA-ESD and C-ESD. No filters for language or date of publication were used. Outcomes included complete resection rate, resected specimen size, procedure time, hemostasis usage (frequency), overall complication rate, perforation rate, and delayed bleeding rate. We used the mean difference (MD) for continuous outcomes in a random-effects model and Peto odds ratio (POR) for binary outcomes where any zero cell existed. Effect sizes and their 95 % confidence intervals (CIs) were determined.
Results:
12 out of 929 identified articles, including 1499 patients, were analyzed. According to pooled results, TA-ESD produced similar R0 resections to C-ESD, but its procedure time (minutes) was shorter than that of C-ESD (MD - 16.02, 95 %CI - 22.71 to - 9.33). Moreover, TA-ESD had a lower complication rate (POR 0.47, 95 %CI 0.29 to 0.76) and perforation rate (POR 0.24, 95 %CI 0.10 to 0.56) than C-ESD. A nonsignificant difference in delayed bleeding rate was observed, although there was a trend toward this being lower in TA-ESD than C-ESD (POR 0.90, 95 %CI 0.46 to 1.75, I 2 = 12 %).
Conclusions:
The traction-assisted strategy improves safety and efficacy in the treatment of patients with ESD. However, we observed different effect sizes in the esophagus, stomach, and colorectum.