UPLC-MS/MS method for determination of retinol and α-tocopherol in serum using a simple sample pretreatment and
Nele Peersman1, Jan Van Elslande1, Yannick Lepage1
1Clinical Department of Laboratory Medicine, University Hospitals Leuven, Leuven, Belgium.
Abstract:
Background Our goal was to develop a simple, rapid and precise ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the determination of retinol and α-tocopherol in serum. Currently published LC-MS/MS methods either require complex extraction procedures (liquid-liquid or solid-phase) or do not meet desirable specifications for imprecision in serum (coefficient of variation [CV] <6.8% and 6.9%, respectively). Methods Sample preparation consisted of a simple protein precipitation with ethanol and acetonitrile. Stable isotope-labeled internal standards (IS) and a homemade calibration curve were used for quantification. The analysis was performed using an Acquity I-class Xevo TQ XS LC-MS/MS. Chromatographic runtime was 6.0 min using a reversed phase gradient elution. UniSpray (US) as an ionization technique was compared to electrospray ionization (ESI). Analytical validation included matrix effect, recovery and trueness compared to National Institute of Standards and Technology (NIST) standards and United Kingdom National External Quality Assessment Service (UK NEQAS) samples. Results Intra- and inter-run CVs were <4.9% for retinol and <1.7% for α-tocopherol, both complying with desirable specifications for imprecision. Bias compared to NIST standards was <3.1% for both compounds. The method was linear over the entire tested range. The lower limit of quantification (LLOQ) with US was lower than with ESI for both retinol (0.022 vs. 0.043 mg/L) and α-tocopherol (0.22 vs. 0.87 mg/L). Matrix effects were not significant (<15%) for retinol. However, for α-tocopherol matrix effects of on average 54.0% were noted using ESI, but not with US. Conclusions We developed a fast, precise and accurate UPLC-MS/MS method for the determination of retinol and α-tocopherol in human serum using a single-step sample pretreatment. Ionization using US eliminated the matrix effects for α-tocopherol.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017