Sensitivity of 2DEG-based Hall-effect sensors at high temperatures
H S Alpert1, C A Chapin1, K M Dowling2
1Department of Aeronautics and Astronautics, Stanford University, Stanford, California 94305, USA.
Abstract:
The magnetic sensitivity of Hall-effect sensors made of InAlN/GaN and AlGaN/GaN heterostructures was measured between room temperature and 576 °C. Both devices showed decreasing voltage-scaled magnetic sensitivity at high temperatures, declining from 53 mV/V/T to 8.3 mV/V/T for the InAlN/GaN sample and from 89 mV/V/T to 8.5 mV/V/T for the AlGaN/GaN sample, corresponding to the decreasing electron mobility due to scattering effects at elevated temperatures. Alternatively, current-scaled sensitivities remained stable over the temperature range, only varying by 13.1% from the mean of 26.3 V/A/T and 10.5% from the mean of 60.2 V/A/T for the InAlN/GaN and AlGaN/GaN samples, respectively. This is due to the minimal temperature dependence of the electron sheet density on the 2-dimensional electron gas (2DEG). Both devices showed consistency in their voltage- and current-scaled sensitivity over multiple temperature cycles as well as nearly full recovery when returned to room temperature after thermal cycling. Additionally, an AlGaN/GaN sample held at 576 °C for 12 h also showed nearly full recovery at room temperature, further suggesting that GaN-based Hall-effect sensors are a good candidate for use in high temperature applications.
More Related Videos
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Related Concept Videos
The Hall Effect
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
Ferromagnetism
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Effect of Temperature Change on Reaction Rate
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...