Comprehensive Evaluation of Rhythm Monitoring Strategies in Screening for Atrial Fibrillation: Insights From Patients
Søren Zöga Diederichsen1, Ketil Jørgen Haugan2, Christian Kronborg3
1Department of Cardiology, Rigshospitalet (S.Z.D., L.K., J.H.S.).
Screening for atrial fibrillation (AF) using implantable loop recorders is more effective than shorter monitoring. Diagnostic yield for AF detection increases with longer, dispersed, and repeated screenings, especially in older males with higher NT-proBNP.
Area of Science:
- Cardiology
- Public Health
- Medical Technology
Background:
- Stroke is a growing global health concern.
- Atrial fibrillation (AF) is a primary stroke risk factor, increasing the importance of AF screening.
- Emerging monitoring technologies are driving advancements in AF detection strategies.
Purpose of the Study:
- To evaluate the performance of various screening strategies for detecting atrial fibrillation (AF).
- To assess population characteristics associated with higher diagnostic yield in AF screening.
- To compare the effectiveness of different monitoring durations and frequencies against implantable loop recorders.
Main Methods:
- Recruited individuals with stroke risk factors but no AF for screening using implantable loop recorders.
- Monitored participants continuously for over 3 years, reconstructing detailed heart rhythm data.
- Simulated various screening strategies using random sampling to assess sensitivity and negative predictive value compared to the loop recorder.
Main Results:
- A single 10-second ECG had low sensitivity (1.5%) for AF detection, while 30 days of continuous monitoring reached 34% sensitivity.
- Increased sensitivity was observed with longer monitoring durations, dispersed monitoring periods, and repeated screenings.
- Higher sensitivity for AF detection was consistently found in older participants (≥75 years), males, those with higher CHADS₂ scores (>2), and elevated NT-proBNP levels (≥40 pmol/L).
Conclusions:
- The diagnostic yield of AF screening strategies increases with monitoring duration, dispersion, and frequency.
- All tested screening strategies showed lower yield compared to continuous monitoring with an implantable loop recorder.
- Older age, male sex, and elevated NT-proBNP are associated with higher sensitivity in AF screening.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias VII: Nursing Management of Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias