Optimize non-contrast head CT imaging tasks using multiple virtual monochromatic image sets in dual-energy spectral
Xiaohu Li1, Zhijie Li1, Jianying Li2
1Department of Radiology, the First Affiliated Hospital of Anhui Medical University, Hefei, China.
Objective:
To demonstrate the value of optimizing non-contrast head imaging tasks by using the multiple virtual monochromatic spectral imaging (VMSI) sets in dual-energy spectral computed tomography (CT) and determine the optimal energy levels for various tasks in imaging head.
Materials And Methods:
This retrospective study includes 55 patients (29 women and 26 men, average age of 54.5±12.3years) who underwent non-contrast head CT in spectral imaging mode. For each patient, 21 VMSI sets from 40 to 140 keV at 5 keV intervals and 120 kVp-like image were reconstructed. Signal-to-noise ratio (SNR) for gray matter (GM) and white matter (WM), contrast-to-noise ratio (CNR) between GM and WM, subcalvarial artifact index (SAI) and posterior fossa artifact index (PFAI) were measured by placing regions-of-interest (ROIs) in nine areas of the brain. Two radiologists subjectively rated the image quality in terms of GM-WM differentiation, beam hardening artifacts in the subcalvarial space, and posterior fossa. The overall image noise was evaluated using a 5-point Likert scale. Measurement data were then statistically analyzed.
Results:
The optimal energy level for viewing the supratentorial brain and reducing beam hardening artifacts in the subcalvarial space and posterior fossa was 65 keV and 75 keV, respectively. All corresponding measurements at these energy levels were significantly better than those measured at other energy levels (all P < 0.05).
Conclusions:
Dual-energy spectral CT imaging provides a set of virtual monochromatic spectral imaging and can be selected on-demand to optimize the imaging tasks in non-contrast head CT. VMSI reconstruction of dual-energy unenhanced head CT scans at 65-75 keV enables to maximize image quality.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT