Related Experiment Video
Updated: Dec 27, 2025

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Separation Performance of Capillary Gas Chromatography Based on Monohydroxycucurbit[7]Uril Incorporated Into Sol-Gels
Jing He1, Jingfeng Ran1, Jianmei Yao1
1School of Chemistry and Chemical Engineering, Guizhou University, Guiyang, China.
Abstract:
A novel monohydroxycucurbit[7]uril-based stationary phase for capillary gas chromatography (GC) has been produced. For this, a capillary column coating was made using a sol-gel technique, incorporating synthesized monohydroxycucurbit[7]uril [(OH)Q[7]] and hydroxy-terminated poly(dimethylsiloxane) (OH-PDMS) into the sol-gel network through hydrolysis and polycondensation and chemical sol-gel grafting to the inner wall of a fused-silica tube. The preparation method may produce a coating with greater integrity, which gives the prepared column a higher separation efficiency and better selectivity toward analytes than a reported stationary phase based on neat cucurbit[n]urils (Q[n]s). The prepared (OH)Q[7]/PDMS column had 3,225 theoretical plates per meter determined using naphthalene at 120°C and exhibited a weakly polar nature. The (OH)Q[7]/PDMS column has high resolution over a broad spectrum of analytes with symmetrical peak shapes and exhibited better separation performance than commercial capillary columns and reported columns based on neat Q[n]s that failed to resolve some critical analytes. Moreover, the column also showed good thermal stability up to 300°C and separation repeatability with relative standard deviation values in the range of 0.01-0.11% for intraday, 0.11-0.32% for interday and 0.29-0.58% for column-to-column. In addition, the energy effect on the retention of analytes on the (OH)Q[7]/PDMS stationary phase was investigated. The results indicated that retention on the column was determined mainly by the enthalpy change. As demonstrated, the proposed coating method can address some disadvantages that exist with the reported Q[n]s columns and combine the full advantages of (OH)Q[7] with the sol-gel coating method while achieving outstanding GC separation performance.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...

