Related Experiment Video
Updated: Dec 27, 2025

Fabrication of Mechanically Tunable and Bioactive Metal Scaffolds for Biomedical Applications
Published on: December 8, 2015
Reducing MRI susceptibility artefacts in implants using additively manufactured porous Ti-6Al-4V structures
Luke N Carter1, Owen Addison2, Nashwan Naji3
1School of Chemical Engineering, College of Engineering and Physical Sciences, University of Birmingham, Edgbaston, UK. B15 2TT.
Abstract:
Magnetic Resonance Imaging (MRI) is critical in diagnosing post-operative complications following implant surgery and imaging anatomy adjacent to implants. Increasing field strengths and use of gradient-echo sequences have highlighted difficulties from susceptibility artefacts in scan data. Artefacts manifest around metal implants, including those made from titanium alloys, making detection of complications (e.g. bleeding, infection) difficult and hindering imaging of surrounding structures such as the brain or inner ear. Existing research focusses on post-processing and unorthodox scan sequences to better capture data around these devices. This study proposes a complementary up-stream design approach using lightweight structures produced via additive manufacturing (AM). Strategic implant mass reduction presents a potential tool in managing artefacts. Uniform specimens of Ti-6Al-4V structures, including lattices, were produced using the AM process, selective laser melting, with various unit cell designs and relative densities (3.1%-96.7%). Samples, submerged in water, were imaged in a 3T MRI system using clinically relevant sequences. Artefacts were quantified by image analysis revealing a strong linear relationship (RR2 = 0.99) between severity and relative sample density. Likewise, distortion due to slice selection errors showed a squared relationship (RR2 = 0.92) with sample density. Unique artefact features were identified surrounding honeycomb samples suggesting a complex relationship exists for larger unit cells. To demonstrate clinical utility, a honeycomb design was applied to a representative cranioplasty. Analysis revealed 10% artefact reduction compared to traditional solid material illustrating the feasibility of this approach. This study provides a basis to strategically design implants to reduce MRI artefacts and improve post-operative diagnosis capability. STATEMENT OF SIGNIFICANCE: MRI susceptibility artefacts surrounding metal implants present a clinical challenge for the diagnosis of post-operative complications relating to the implant itself or underlying anatomy. In this study for the first time we demonstrate that additive manufacturing may be exploited to create lattice structures that predictably reduce MRI image artefact severity surrounding titanium alloy implants. Specifically, a direct correlation of artefact severity, both total signal loss and distortion, with the relative material density of these functionalised materials has been demonstrated within clinically relevant MRI sequences. This approach opens the door for strategic implant design, utilising this structurally functionalised material, that may improve post-operative patient outcomes and compliments existing efforts in this area which focus on data acquisition and post-processing methods.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
12:19Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...