Related Experiment Video
Updated: Dec 27, 2025

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Real-time Estimation of Temperature Time Derivative in Inertial Measurement Unit by Finite-Impulse-Response
Alexander Kozlov1, Ilya Tarygin1
1Lomonosov Moscow State University, Faculty of Mechanics and Mathematics, Navigation and Control Lab. Leninskiye Gory, Main Building, 119991 Moscow, Russia.
Abstract:
We present a filtering technique that allows estimating the time derivative of slowly changing temperature measured via quantized sensor output in real time. Due to quantization, the output may appear constant for several minutes in a row with the temperature actually changing over time. Another issue is that measurement errors do not represent any kind of white noise. Being typically the case in high-grade inertial navigation systems, these phenomena amid slow variations of temperature prevent any kind of straightforward assessment of its time derivative, which is required for compensating hysteresis-like thermal effects in inertial sensors. The method is based on a short-term temperature prediction represented by an exponentially decaying function, and on the finite-impulse-response Kalman filtering in its numerically stable square-root form, employed for estimating model parameters in real time. Instead of using all of the measurements, the estimation involves only those received when quantized sensor output is updated. We compare the technique against both an ordinary averaging numerical differentiator and a conventional Kalman filter, over a set of real samples recorded from the inertial unit.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...

