Iterative local Fourier transform-based high-accuracy wavelength calibration for Fourier transform imaging
Abstract:
An iterative local Fourier transform (ILFT)-based high-accuracy wavelength calibration for Fourier transform imaging spectrometer (FTIS) is proposed. The wavelength calibration for FTIS is to determine the relation between the wavelength and the wavenumber position. However, the wavenumber position solved by conventional method is only accurate up to integers restricted by the picket-fence effect of discrete Fourier transform. While the proposed ILFT can increase the accuracy of calculating the wavenumber position by combining the local Fourier transform and a few iterations. In this paper, the method is investigated in theory and then by simulations and experiments. The simulations show that the accuracy of the wavenumber position calculated by the ILFT is increased by 100 times than conventional method with noise, phase error, and non-uniform sampling of optical path difference. And the experimental results indicate that the ILFT decreases the absolute error of wavelength calibration from about 2.03 nm to 0.16 nm. Therefore, the method provides theoretical and technical support for FTIS and promotes the development of superior resolutions therein.
More Related Videos
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Related Concept Videos
IR Spectrometers
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Continuous -time Fourier Transform