Related Experiment Video
Updated: Dec 27, 2025

Study Design for Navigated Repetitive Transcranial Magnetic Stimulation for Speech Cortical Mapping
Published on: March 24, 2023
Concordance Between Transcranial Magnetic Stimulation and Functional Magnetic Resonance Imaging (MRI) Derived
Katherine Schiller1, Asim F Choudhri2,3,4, Tamekia Jones1,5
1Department of Pediatrics, Division of Pediatric Neurology, University of Tennessee Health Science Center, Memphis, TN, USA.
Abstract:
Transcranial magnetic stimulation (TMS) is a newer noninvasive language mapping tool that is safe and well-tolerated by children. We examined the accuracy of TMS-derived language maps in a clinical cohort by comparing it against functional magnetic resonance imaging (MRI)-derived language map. The number of TMS-induced speech disruptions and the volume of activation during functional MRI tasks were localized to Brodmann areas for each modality in 40 patients with epilepsy or brain tumor. We examined the concordance between TMS- and functional MRI-derived language maps by deriving statistical performance metrics for TMS including sensitivity, specificity, accuracy, and diagnostic odds ratio. Brodmann areas 6, 44, and 9 in the frontal lobe and 22 and 40 in the temporal lobe were the most commonly identified language areas by both modalities. Overall accuracy of TMS compared to functional MRI in localizing language cortex was 71%, with a diagnostic odds ratio of 1.27 and higher sensitivity when identifying left hemisphere regions. TMS was more accurate in determining the dominant hemisphere for language with a diagnostic odds ratio of 6. This study is the first to examine the accuracy of the whole brain language map derived by TMS in the largest cohort examined to date. While this comparison against functional MRI confirmed that TMS reliably localizes cortical areas that are not essential for speech function, it demonstrated only slight concordance between TMS- and functional MRI-derived language areas. That the localization of specific language cortices by TMS demonstrated low accuracy reveals a potential need to use concordant tasks between the modalities and other avenues for further optimization of TMS parameters.
More Related Videos
10:15Utilizing Repetitive Transcranial Magnetic Stimulation to Improve Language Function in Stroke Patients with Chronic Non-fluent Aphasia
Published on: July 2, 2013
09:30Localizing Function-specific Targets for Transcranial Magnetic Stimulation in the Absence of Navigation Equipment
Published on: May 23, 2025