Immunoassay Interference on Thyroid Function Tests During Treatment with Nivolumab
Rosa Maria Paragliola1, Andrea Corsello1, Giampaolo Papi1
1Department of Endocrinology and Università Cattolica del Sacro Cuore-Fondazione Policlinico "Gemelli" IRCCS, Rome, Italy.
Immune checkpoint inhibitors (ICIs) are associated with several endocrine side effects. In particular, the use of programmed cell death protein-1 (PD-1)/programmed cell death-ligand 1 (PD-L1) inhibitors is related to a higher incidence of thyroid dysfunction. An 85 years-old patient, diagnosed with a metastatic melanoma treated with nivolumab, presented to our hospital with severe ICI-related thyrotoxicosis. Diagnosis was complicated by a biochemical interference on thyroid hormones assay, probably induced by nivolumab. Baseline laboratory examination conducted before onset of anticancer therapy showed normal thyroid function test (TFTs). A few days after receiving the second nivolumab administration, the patient developed a severe thyrotoxicosis. According to destructive thyroiditis, in a short period thyrotropin (TSH) levels normalized and rapidly increased, but free thyroxine (fT4) levels were inappropriately elevated and did not decrease as expected. The sample was processed by using a Siemens Centaur® immunoassay. We reanalyzed the same sample at another laboratory and with a different immunoassay method (Roche Elecsys®). The results obtained from this assay confirmed severe hypothyroidism with appropriately low fT4 levels. We suspected a possible nivolumab-associated interference on the fT4 assay. Therefore, we subjected the same sample to a polyethylene glycol (PEG) 6000 precipitation, a simple method for the removal of macromolecules, before assaying for fT4 levels. Evaluation of the post-PEG-precipitation sample (Siemens Centaur immunoassay) revealed appropriately low fT4 levels. The patient was started on levothyroxine (LT4) therapy, with monthly TFT monitoring using the Roche immunoassay. Approximately 9 months after starting nivolumab therapy, the patient was advised treatment cessation. A month later, the TFTs were retested on a Siemens Centaur immunoassay, and appropriate fT4 levels were observed in accordance with normal TSH levels on adequate LT4 replacement therapy. We report a possible novel nivolumab-induced biochemical interference on assays of fT4 levels. The hypothesis of a biochemical drug-induced interference is further supported by the disappearance of the interference after the withdrawal of nivolumab. Further studies are needed to prove the biochemical mechanisms of this interference.
Immune checkpoint inhibitors (ICIs) are associated with several endocrine side effects. In particular, the use of programmed cell death protein-1 (PD-1)/programmed cell death-ligand 1 (PD-L1) inhibitors is related to a higher incidence of thyroid dysfunction. An 85 years-old patient, diagnosed with a metastatic melanoma treated with nivolumab, presented to our hospital with severe ICI-related thyrotoxicosis. Diagnosis was complicated by a biochemical interference on thyroid hormones assay, probably induced by nivolumab. Baseline laboratory examination conducted before onset of anticancer therapy showed normal thyroid function test (TFTs). A few days after receiving the second nivolumab administration, the patient developed a severe thyrotoxicosis. According to destructive thyroiditis, in a short period thyrotropin (TSH) levels normalized and rapidly increased, but free thyroxine (fT4) levels were inappropriately elevated and did not decrease as expected. The sample was processed by using a Siemens Centaur® immunoassay. We reanalyzed the same sample at another laboratory and with a different immunoassay method (Roche Elecsys®). The results obtained from this assay confirmed severe hypothyroidism with appropriately low fT4 levels. We suspected a possible nivolumab-associated interference on the fT4 assay. Therefore, we subjected the same sample to a polyethylene glycol (PEG) 6000 precipitation, a simple method for the removal of macromolecules, before assaying for fT4 levels. Evaluation of the post-PEG-precipitation sample (Siemens Centaur immunoassay) revealed appropriately low fT4 levels. The patient was started on levothyroxine (LT4) therapy, with monthly TFT monitoring using the Roche immunoassay. Approximately 9 months after starting nivolumab therapy, the patient was advised treatment cessation. A month later, the TFTs were retested on a Siemens Centaur immunoassay, and appropriate fT4 levels were observed in accordance with normal TSH levels on adequate LT4 replacement therapy. We report a possible novel nivolumab-induced biochemical interference on assays of fT4 levels. The hypothesis of a biochemical drug-induced interference is further supported by the disappearance of the interference after the withdrawal of nivolumab. Further studies are needed to prove the biochemical mechanisms of this interference.
More Related Videos
Related Concept Videos
Therapeutic Drug Monitoring: Affecting Factors
Tumor Immunotherapy
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...