Related Experiment Video
Updated: Dec 27, 2025

The Quantification of Injectability by Mechanical Testing
Published on: May 13, 2020
Performance of single-use syringe versus multi-use MR contrast injectors: a prospective comparative study
F Struik1, J J Futterer2, W M Prokop2
1Department of Radiology and Nuclear Medicine, Radboudumc, Nijmegen, The Netherlands. struikfe@gmail.com.
Abstract:
The goal of this study was to compare performance parameters of a single-use syringe and a multi-use MR contrast injector. We compared preparation time, cost for disposables and volumes of contrast material used for a single-use (SI) and a multi-use (MI) MR contrast injector in a prospective cross-over trial. During the first study period all consecutive patients eligible for dynamic MR on two systems were included during a period of 20 working days. After 10 days, the injector was switched. Radiographer satisfaction was evaluated using a questionnaire. Contrast usage and waste on system MI was optimised by extra instructions for our radiographers and measured during the second study period of 10 consecutive working days. A total of 202 and 163 patients for systems SI and MI were included, respectively. Average preparation time was 4:55 min for SI and 2:24 min for MI (p < 0.05). Contrast waste for SI was 13% using 7.5 ml syringes. Contrast waste for MI was 5% for 7.5 ml containers. Costs for disposables were lower for MI if more than 5 patients per day were injected. Radiographer satisfaction was higher for MI (4.7 versus 2.8 on a 5-point scale; p < 0.05). The multi-use MR contrast injector led to higher radiographer satisfaction, shorter preparation time, and lower cost if more than 5 patients were injected per day. In addition, cheaper contrast containers of 15 or 30 ml could be used for the first patients if more than 2 or more than 4 injections are performed per day, potentially leading to lower contrast waste.
More Related Videos
06:47Echocardiography-guided Injection for Targeted and Reliable Intramyocardial Stem Cell Delivery in a Rat Model of Myocardial Infarction
Published on: July 25, 2025
06:19Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024
Related Concept Videos
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Bioavailability Study Design: Single Versus Multiple Dose Studies
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Bioequivalence of Drugs: Drugs with Multiple Indications