Related Experiment Video
Updated: Dec 27, 2025

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Effect of dynamic position changes during colonoscope withdrawal: a meta-analysis of randomized controlled trials
Peiwen Li1, Bin Ma2, Shulei Gong1
1Department of Thoracic Surgery, The First Hospital of China Medical University, No.155 North Nanjing Street, Shenyang, 110001, People's Republic of China.
Background:
Colonoscopies are considered to be the primary screening test and gold standard test for colorectal cancer. Position changes during colonoscope withdrawal are believed to be associated with an increased adenoma detection rate (ADR) and polyp detection rate (PDR). However, previous results conflicted, and this study aimed to elucidate the effectiveness of dynamic position changes during colonoscope withdrawal.
Methods:
The relevant publications were identified by searching the medical databases. The primary outcomes were the ADR and PDR, which were pooled and analyzed. The secondary outcome was the withdrawal time. The studies that supplied the ADR and PDR for different segments of the colon were separated into subgroup analyses.
Results:
Five randomized controlled trials were eligible for analysis. The total ADR was higher with dynamic position changes than with a static position (odds ratio, [OR] 1.34; 95% confidence interval [CI] 1.13-1.59; p < 0.001), with low evidence of between-study heterogeneity (I2 = 0%). Although the total PDR was slightly higher with dynamic position changes than with a static position (OR 1.23; 95% CI 0.88-1.73), there difference was not statistically significant (p = 0.22). The withdrawal time was only increased by 0.47 min (95% CI - 0.11 to 1.06) with dynamic position changes, without statistical significance (p = 0.11). The subgroup analysis showed that the ADR and PDR for the transverse colon were higher with dynamic position changes, with pooled estimates of ADR (OR 1.72; 95% CI 1.02-2.88; p = 0.04) and PDR (OR 1.79; 95% CI 1.08-2.96; p = 0.02).
Conclusion:
Dynamic position changes during colonoscope withdrawal increased the total ADR; however, no obvious increase was found in the total PDR. The withdrawal time was not significantly prolonged with dynamic position changes. Subgroup analysis showed that the ADR and PDR in the transverse colon were obviously improved with dynamic position changes.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...