Intracardiac echocardiography use and outcomes after catheter ablation of ventricular tachycardia
Michael E Field1, Laura Goldstein2, Stephanie Hsiao Yu Lee3
1Department of Medicine, Medical University of South Carolina, Charleston, SC, USA.
Insights
Intracardiac echocardiography (ICE) during ventricular tachycardia (VT) ablation in patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator significantly reduces VT-related readmissions. This approach improves patient outcomes and lowers healthcare utilization.
Area of Science:
- Cardiology
- Medical Devices
- Electrophysiology
Background:
- Ventricular tachycardia (VT) ablation is a critical procedure for patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D).
- Optimizing ablation outcomes and reducing readmissions remain key challenges in managing these complex patients.
Purpose of the Study:
- To compare the effectiveness of outpatient VT catheter ablation with and without intracardiac echocardiography (ICE) in patients with ICD/CRT-D devices.
- To assess the impact of ICE use on various patient readmission outcomes.
Main Methods:
- A retrospective study comparing patients undergoing VT ablation with (n=1143) and without (n=1677) ICE, identified via procedure codes.
- Propensity score matching was employed to control for confounding variables.
- Survival analyses and falsification outcomes were used to evaluate the association between ICE use and readmissions.
Main Results:
- Patients who underwent VT ablation with ICE demonstrated a 24% lower risk of all-cause readmissions.
- A 24% reduction in cardiovascular-related and a 20% reduction in VT-related readmissions were observed in the ICE group compared to the non-ICE group.
- Falsification analyses confirmed the robustness of the association between ICE use and improved outcomes, with nonsignificant results for spurious associations.
Conclusions:
- Intracardiac echocardiography (ICE) use during outpatient VT ablation in patients with ICD/CRT-D devices is associated with significantly lower VT-related readmission rates.
- The findings suggest that ICE is a valuable tool for improving procedural success and reducing long-term complications in this patient population.
Abstract:
Aim: To compare outcomes among patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing outpatient ventricular tachycardia (VT) catheter ablation using intracardiac echocardiography (ICE) versus no ICE. Patients & methods: Patients were classified into ICE (n = 1143)/non-ICE (n = 1677) groups based on ICE procedure codes. Patients in each group were propensity matched on study covariates. Survival analyses were used to assess outcomes. To examine residual confounding, falsification outcomes were evaluated. Results: ICE patients had a 24% lower risk of all-cause readmissions, 24% lower risk of cardiovascular-related and 20% lower risk of VT-related readmissions compared with non-ICE patients. Falsification analyses for ICE use association were nonsignificant. Conclusion: Patients with implantable cardioverter defibrillator/cardiac resynchronization therapy-defibrillator undergoing VT ablation with ICE use had significantly lower likelihood of VT-related readmission.
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiopulmonary Resuscitation III: AED Use
Cardiac Catheterization II: Right Heart Catheterization
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias