Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Towards the determination of an equivalent standard column set between cryogenic and flow-modulated comprehensive
Ivan Aloisi1, Tiago Schena2, Barbara Giocastro1
1Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy.
Abstract:
This preliminary research is focused on the task of defining an equivalent standard column set between cryogenic and flow-modulation comprehensive two-dimensional gas chromatography (GC × GC) combined with mass spectrometry (MS). Cryogenic modulation (CM) was carried out by using a loop-type device, while the flow modulator used was a seven-port wafer chip, equipped with an external accumulation loop. Initially, a common low-polarity + mid-polarity CM GC × GC column set was selected (30 m × 0.25 mm ID × 0.25 μm df + 1.5 m × 0.25 mm ID × 0.25 μm df), a method was developed, and a GC × GC-MS fingerprint was attained (on a sample of bio-oil derived from coconut fibers). After, a column set with the same stationary phases was selected for the flow modulation GC × GC-MS method (20 m × 0.18 mm ID × 0.18 μm df + 5 m × 0.32 mm ID × 0.25 μm df), with the capability to provide a-similar-as-possible separation. A side-by-side measurement of several chromatography parameters (efficiency, peak capacity, resolution, peak widths, retention factors, elution temperatures) was made.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Types Of Column Chromatography
Gel Filtration Chromatography
When the...